Programming an ORION CE Endpoint
1. Double-tap the reading in the Reading eld box as
shown in Figure 134.
Result: The current reading in the eld is highlighted.
Figure 134: ORION CE IR programming screen
2. Using the handheld keypad, enter the RTR odometer value in the Reading eld.
Refer to "Setting the Odometer" onpage50 for more information.
Result: The inside of the reading box turns pink (Figure 135) to indicate a new value is entered in the field but not yet
programmed.
NOT: N Leading zeros are not required, however it may be helpful to enter leading zeros as visual confirmation. Only
seven digits can be entered when programming an endpoint, regardless of the meter size.
3. Align the optical read head of the IR cable with the ORION ME endpoint IR port and tap Program.
Result: The new value is programmed and the reading box is no longer pink. See Figure 136.
Figure 135: New reading value entered
Figure 136: New reading value programmed
NOT: N When programming an endpoint after clearing a tamper, verify that the programming and wire splicing were
successful. Tap ORION CE RF Quick Read - Single and tap Start Reading to perform a Quick Read on the endpoint.
If the endpoint still reports a tamper, check the wire splices, repair as necessary and repeat the programming
procedure above.
ORION® Automated Meter Reading System for Trimble® Ranger 3
Page 76 February 2013