ADE Extended Status
Figure 91: Extended Status - ADE
The status indicators described below apply for an ORION ME or SE (mobile mode) endpoint when connected to an
ADE encoder.
Status Indicator Description
Mobile Mode Endpoint is communicating in mobile transmission mode.
IR Programmed Endpoint has been reprogrammed via IR.
Low Battery Endpoint is reporting a low battery condition.
Tamper Endpoint is reporting a tamper condition. This condition occurs when the wire between the register
and the endpoint is cut or shorted, or the encoder is not connected.
Encoder Error Device error reported by the endpoint when the encoder exhibits a temporary or permanent failure
to extract the current reading.
No Usage Endpoint is reporting a no usage condition. This condition occurs when there is no water flow
registered over a 30-day time frame.
Leak Endpoint is reporting a potential leak condition when there is continuous usage over a 24-hour time
period without a 2-hour period of non-usage.
Reverse Flow Encoder is reporting a reverse flow condition to the endpoint.
Encoder Information Description
Size & Type The size and type of the meter for which the encoder was programmed. Tap the button to change
the meter size and type.
Units The units of measure as defined by the encoder: cubic meters, cubic feet, gallons, imperial gallons or
liters. Tap the button to change the units.
Encoder The encoder protocol.
Dials The encoder dial resolution (4-, 5- or 6-dials) as reported from the encoder.
NOT: N Refer to the ORION Water Endpoint Technical Brief, ORI-T-58-EN, for complete information.