ORION ME ENDPOINT UTILITY
The ORION ME endpoint utility functions are used for IR programming and IR/RF historical interval data extraction. This
selection is also used to assist in fixed network installation.
Figure 81: ORION ME menu
There are five options as shown in Figure 81. Each option is described in detail in this section.
ORION ME IR Programming Used to read and program ORION SE and ME water and gas endpoints using the IR
programming cable. This option is also used to program an endpoint following a
tamper repair or retrofit installation (RTR water installations only). Refer to "ORION
ME IR Programming" onpage48.
For instructions on programming a gas endpoint, refer to "Programming an ORION
ME Gas Endpoint" onpage71.
ORION ME RF Quick Read–All Used to quick read all ORION ME and SE (in mobile mode) endpoints within range
of the handheld. Refer to "ORION ME RF Quick Read-All" onpage62.
ORION ME RF Quick Read–Single Used to quick read a specific ORION ME or SE (in mobile mode) endpoint serial
number. Refer to"ORION ME RF Quick Read-Single" onpage64.
ORION ME Profiling Used to perform an IR or RF extraction of an endpoint's historical interval data
for viewing in the ORION Profile Viewer software. Refer to"ORION ME Profiling"
onpage66.
ORION SE/ME Installation Used to set a GPS location for an endpoint. Also used to let an installer know that
the ORION SE endpoint is being heard from at least one gateway when it is placed
into position and that it will switch over to fixed network mode. Refer to
"ORION SE / ME Installation" onpage69.
NOT: N Before continuing, make sure the IR programming cable is connected if it is being used and the COM ports (IR, RF,
GPS) are set correctly. Refer to "Settings for Program & Quick Read" onpage86 if you need help.
Tap to select a menu option.
Installation & Operation Manual
Page 47 February 2013